mirror of
https://github.com/idanoo/nzart-exam-generator.git
synced 2024-12-04 22:26:58 +00:00
266 lines
4.5 KiB
Plaintext
266 lines
4.5 KiB
Plaintext
|
% FILENAME = N20.TXT
|
||
|
% Harmonics and Parasitics
|
||
|
% Release version 2, January 00
|
||
|
|
||
|
%QUESTION: 1
|
||
|
#20.1 A harmonic of a signal transmitted at 3525 kHz would be expected to occur at:
|
||
|
|
||
|
3573 kHz
|
||
|
|
||
|
7050 kHz
|
||
|
|
||
|
14025 kHz
|
||
|
|
||
|
21050 kHz
|
||
|
|
||
|
% ans 2
|
||
|
|
||
|
%QUESTION: 2
|
||
|
#20.2 The third harmonic of 7 MHz is:
|
||
|
|
||
|
10 MHz
|
||
|
|
||
|
14 MHz
|
||
|
|
||
|
21 MHz
|
||
|
|
||
|
28 MHz
|
||
|
|
||
|
% ans 3
|
||
|
|
||
|
%QUESTION: 3
|
||
|
#20.3 The fifth harmonic of 7 MHz is:
|
||
|
|
||
|
12 MHz
|
||
|
|
||
|
19 MHz
|
||
|
|
||
|
28 MHz
|
||
|
|
||
|
35 MHz
|
||
|
|
||
|
% ans 4
|
||
|
|
||
|
%QUESTION: 4
|
||
|
#20.4 Excessive harmonic output may be produced in a transmitter by:
|
||
|
|
||
|
a linear amplifier
|
||
|
|
||
|
a low SWR
|
||
|
|
||
|
resonant circuits
|
||
|
|
||
|
overdriven amplifier stages
|
||
|
|
||
|
% ans 4
|
||
|
|
||
|
%QUESTION: 5
|
||
|
#20.5 Harmonics may be produced in the RF power amplifier of a transmitter if:
|
||
|
|
||
|
the modulation level is too low
|
||
|
|
||
|
the modulation level is too high
|
||
|
|
||
|
the oscillator frequency is unstable
|
||
|
|
||
|
modulation is applied to more than one stage
|
||
|
|
||
|
% ans 2
|
||
|
|
||
|
%QUESTION: 6
|
||
|
#20.6 Harmonics produced in an early stage of a transmitter may be reduced in a later stage by:
|
||
|
|
||
|
increasing the signal input to the final stage
|
||
|
|
||
|
using FET power amplifiers
|
||
|
|
||
|
using tuned circuit coupling between stages
|
||
|
|
||
|
using larger value coupling capacitors
|
||
|
|
||
|
% ans 3
|
||
|
|
||
|
%QUESTION: 7
|
||
|
#20.7 Harmonics are produced when:
|
||
|
|
||
|
a resonant circuit is detuned
|
||
|
|
||
|
negative feedback is applied to an amplifier
|
||
|
|
||
|
a transistor is biased for class A operation
|
||
|
|
||
|
a sine wave is distorted
|
||
|
|
||
|
% ans 4
|
||
|
|
||
|
%QUESTION: 8
|
||
|
#20.8 Harmonic frequencies are:
|
||
|
|
||
|
always lower in frequency than the fundamental frequency
|
||
|
|
||
|
at multiples of the fundamental frequency
|
||
|
|
||
|
any unwanted frequency above the fundamental frequency
|
||
|
|
||
|
any frequency causing TVI
|
||
|
|
||
|
% ans 2
|
||
|
|
||
|
%QUESTION: 9
|
||
|
#20.9 An interfering signal from a transmitter has a frequency of 57 MHz. This signal could be the:
|
||
|
|
||
|
seventh harmonic of an 80 meter transmission
|
||
|
|
||
|
third harmonic of a 15 metre transmission
|
||
|
|
||
|
second harmonic of a 10 metre transmission
|
||
|
|
||
|
crystal oscillator operating on its fundamental
|
||
|
|
||
|
% ans 3
|
||
|
|
||
|
%QUESTION: 10
|
||
|
#20.10 To minimise the radiation of one particular harmonic, one can use a:
|
||
|
|
||
|
wave trap in the transmitter output
|
||
|
|
||
|
resistor
|
||
|
|
||
|
high pass filter in the transmitter output
|
||
|
|
||
|
filter in the receiver lead
|
||
|
|
||
|
% ans 1
|
||
|
|
||
|
%QUESTION: 11
|
||
|
#20.11 A low-pass filter is used in the antenna lead from a transmitter:
|
||
|
|
||
|
to reduce key clicks developed in a CW transmitter
|
||
|
|
||
|
to increase harmonic radiation
|
||
|
|
||
|
to eliminate chirp in CW transmissions
|
||
|
|
||
|
to reduce radiation of harmonics
|
||
|
|
||
|
% ans 4
|
||
|
|
||
|
%QUESTION: 12
|
||
|
#20.12 The following is installed in the transmission line as close as possible to a HF transmitter to reduce harmonic output:
|
||
|
|
||
|
a middle-pass filter
|
||
|
|
||
|
a low-pass filter
|
||
|
|
||
|
a high-pass filter
|
||
|
|
||
|
a band-reject filter
|
||
|
|
||
|
% ans 2
|
||
|
|
||
|
%QUESTION: 13
|
||
|
#20.13 A low pass filter will:
|
||
|
|
||
|
suppress sub-harmonics
|
||
|
|
||
|
reduce harmonics
|
||
|
|
||
|
always eliminate interference
|
||
|
|
||
|
improve harmonic radiation
|
||
|
|
||
|
% ans 2
|
||
|
|
||
|
%QUESTION: 14
|
||
|
#20.14 A spurious transmission from a transmitter is:
|
||
|
|
||
|
an unwanted emission unrelated to the output signal frequency
|
||
|
|
||
|
an unwanted emission that is harmonically related to the modulating audio frequency
|
||
|
|
||
|
generated at 50 Hz
|
||
|
|
||
|
the main part of the modulated carrier
|
||
|
|
||
|
% ans 1
|
||
|
|
||
|
%QUESTION: 15
|
||
|
#20.15 A parasitic oscillation:
|
||
|
|
||
|
is an unwanted signal developed in a transmitter
|
||
|
|
||
|
is generated by parasitic elements of a Yagi beam
|
||
|
|
||
|
does not cause any radio interference
|
||
|
|
||
|
is produced in a transmitter oscillator stage
|
||
|
|
||
|
% ans 1
|
||
|
|
||
|
%QUESTION: 16
|
||
|
#20.16 Parasitic oscillations in a RF power amplifier can be suppressed by:
|
||
|
|
||
|
pulsing the supply voltage
|
||
|
|
||
|
placing suitable chokes, ferrite beads or resistors within the amplifier
|
||
|
|
||
|
screening all input leads
|
||
|
|
||
|
using split-stator tuning capacitors
|
||
|
|
||
|
% ans 2
|
||
|
|
||
|
%QUESTION: 17
|
||
|
#20.17 Parasitic oscillations in the RF power amplifier stage of a transmitter may occur:
|
||
|
|
||
|
at low frequencies only
|
||
|
|
||
|
on harmonic frequencies
|
||
|
|
||
|
at high frequencies only
|
||
|
|
||
|
at high or low frequencies
|
||
|
|
||
|
% ans 4
|
||
|
|
||
|
%QUESTION: 18
|
||
|
#20.18 Transmitter power amplifiers can generate parasitic oscillations on:
|
||
|
|
||
|
the transmitter's output frequency
|
||
|
|
||
|
harmonics of the transmitter's output frequency
|
||
|
|
||
|
frequencies unrelated to the transmitter's output frequency
|
||
|
|
||
|
VHF frequencies only
|
||
|
|
||
|
% ans 3
|
||
|
|
||
|
%QUESTION: 19
|
||
|
#20.19 Parasitic oscillations tend to occur in:
|
||
|
|
||
|
high voltage rectifiers
|
||
|
|
||
|
high gain amplifier stages
|
||
|
|
||
|
antenna matching circuits
|
||
|
|
||
|
SWR bridges
|
||
|
|
||
|
% ans 2
|
||
|
|
||
|
%QUESTION: 20
|
||
|
#20.20 Parasitic oscillations can cause interference. They are:
|
||
|
|
||
|
always the same frequency as the mains supply
|
||
|
|
||
|
always twice the operating frequency
|
||
|
|
||
|
not related to the operating frequency
|
||
|
|
||
|
three times the operating frequency
|
||
|
|
||
|
% ans 3
|
||
|
|
||
|
|