% FILENAME = N10.TXT
|
||
|
% Safety
|
||
|
% Release version 2, January 2000
|
||
|
|
||
|
%Question: 1
|
||
|
#10.1 You can safely remove an unconscious person from contact with a high
|
||
|
voltage source by:
|
||
|
|
||
|
pulling an arm or a leg
|
||
|
|
||
|
wrapping the person in a blanket and pulling to a safe area
|
||
|
|
||
|
calling an electrician
|
||
|
|
||
|
turning off the high voltage and then removing the person
|
||
|
|
||
|
% ans 4
|
||
|
|
||
|
%Question: 2
|
||
|
#10.2 For your safety, before checking a fault in a mains operated power supply
|
||
|
unit, first:
|
||
|
|
||
|
short the leads of the filter capacitor
|
||
|
|
||
|
turn off the power and remove the power plug
|
||
|
|
||
|
check the action of the capacitor bleeder resistance
|
||
|
|
||
|
remove and check the fuse in the power supply
|
||
|
|
||
|
% ans 2
|
||
|
|
||
|
%Question: 3
|
||
|
#10.3 Wires carrying high voltages in a transmitter should be well insulated to
|
||
|
avoid:
|
||
|
|
||
|
short circuits
|
||
|
|
||
|
overheating
|
||
|
|
||
|
over modulation
|
||
|
|
||
|
SWR effects
|
||
|
|
||
|
% ans 1
|
||
|
|
||
|
%Question: 4
|
||
|
#10.4 A residual current device is recommended for protection in a mains power
|
||
|
circuit because it:
|
||
|
|
||
|
reduces electrical interference from the circuit
|
||
|
|
||
|
removes power to the circuit when the phase and neutral currents are not equal
|
||
|
|
||
|
removes power to the circuit when the current in the phase wire equals the
|
||
|
current in the earth wire
|
||
|
|
||
|
limits the power provided to the circuit
|
||
|
|
||
|
% ans 2
|
||
|
|
||
|
%Question: 5
|
||
|
#10.5 An earth wire should be connected to the metal chassis of a
|
||
|
mains-operated power supply to ensure that if a fault develops, the chassis:
|
||
|
|
||
|
does not develop a high voltage with respect to earth
|
||
|
|
||
|
does not develop a high voltage with respect to the phase lead
|
||
|
|
||
|
becomes a conductor to bleed away static charge
|
||
|
|
||
|
provides a path to ground in case of lightning strikes
|
||
|
|
||
|
% ans 1
|
||
|
|
||
|
%Question: 6
|
||
|
#10.6 The purpose of using three wires in the mains power cord and plug on
|
||
|
amateur radio equipment is to:
|
||
|
|
||
|
make it inconvenient to use
|
||
|
|
||
|
prevent the chassis from becoming live in case of an internal short to the
|
||
|
chassis
|
||
|
|
||
|
prevent the plug from being reversed in the wall outlet
|
||
|
|
||
|
prevent short circuits
|
||
|
|
||
|
% ans 2
|
||
|
|
||
|
%Question: 7
|
||
|
#10.7 The correct colour coding for the phase wire in a flexible mains lead is:
|
||
|
|
||
|
brown
|
||
|
|
||
|
blue
|
||
|
|
||
|
yellow and green
|
||
|
|
||
|
white
|
||
|
|
||
|
% ans 1
|
||
|
|
||
|
%Question: 8
|
||
|
#10.8 The correct colour coding for the neutral wire in a flexible mains lead
|
||
|
is:
|
||
|
|
||
|
brown
|
||
|
|
||
|
blue
|
||
|
|
||
|
yellow and green
|
||
|
|
||
|
white
|
||
|
|
||
|
% ans 2
|
||
|
|
||
|
%Question: 9
|
||
|
#10.9 The correct colour coding for the earth wire in a flexible mains lead is:
|
||
|
|
||
|
brown
|
||
|
|
||
|
blue
|
||
|
|
||
|
yellow and green
|
||
|
|
||
|
white
|
||
|
|
||
|
% ans 3
|
||
|
|
||
|
%Question: 10
|
||
|
#10.10 An isolating transformer is used to:
|
||
|
|
||
|
ensure that faulty equipment connected to it will blow a fuse in the
|
||
|
distribution board
|
||
|
|
||
|
ensure that no voltage is developed between either output lead and ground
|
||
|
|
||
|
ensure that no voltage is developed between the output leads
|
||
|
|
||
|
step down the mains voltage to a safe value
|
||
|
|
||
|
% ans 2
|
||
|
|
||
|
|