% FILENAME = N10.TXT
% Safety
% Release version 2, January 2000
%Question: 1
#10.1 You can safely remove an unconscious person from contact with a high
voltage source by:
pulling an arm or a leg
wrapping the person in a blanket and pulling to a safe area
calling an electrician
turning off the high voltage and then removing the person
% ans 4
%Question: 2
#10.2 For your safety, before checking a fault in a mains operated power supply
unit, first:
short the leads of the filter capacitor
turn off the power and remove the power plug
check the action of the capacitor bleeder resistance
remove and check the fuse in the power supply
% ans 2
%Question: 3
#10.3 Wires carrying high voltages in a transmitter should be well insulated to
avoid:
short circuits
overheating
over modulation
SWR effects
% ans 1
%Question: 4
#10.4 A residual current device is recommended for protection in a mains power
circuit because it:
reduces electrical interference from the circuit
removes power to the circuit when the phase and neutral currents are not equal
removes power to the circuit when the current in the phase wire equals the
current in the earth wire
limits the power provided to the circuit
% ans 2
%Question: 5
#10.5 An earth wire should be connected to the metal chassis of a
mains-operated power supply to ensure that if a fault develops, the chassis:
does not develop a high voltage with respect to earth
does not develop a high voltage with respect to the phase lead
becomes a conductor to bleed away static charge
provides a path to ground in case of lightning strikes
% ans 1
%Question: 6
#10.6 The purpose of using three wires in the mains power cord and plug on
amateur radio equipment is to:
make it inconvenient to use
prevent the chassis from becoming live in case of an internal short to the
chassis
prevent the plug from being reversed in the wall outlet
prevent short circuits
% ans 2
%Question: 7
#10.7 The correct colour coding for the phase wire in a flexible mains lead is:
brown
blue
yellow and green
white
% ans 1
%Question: 8
#10.8 The correct colour coding for the neutral wire in a flexible mains lead
is:
brown
blue
yellow and green
white
% ans 2
%Question: 9
#10.9 The correct colour coding for the earth wire in a flexible mains lead is:
brown
blue
yellow and green
white
% ans 3
%Question: 10
#10.10 An isolating transformer is used to:
ensure that faulty equipment connected to it will blow a fuse in the
distribution board
ensure that no voltage is developed between either output lead and ground
ensure that no voltage is developed between the output leads
step down the mains voltage to a safe value
% ans 2